Reparatii curente necesare retelei electrice

    SEAP
    ID
    DA30000051
    Data
    22 Februarie 2022
    Valoare
    87.832,36 RON
    Stare
    Oferta acceptata
    Autoritatea contractantaLocalitate
    Bucuresti, Bucuresti
    FurnizorTipul contractului
    Servicii
    Cod CPVDescriere:
    1. UPS 10KVA UPS, dubla conversie, 400V. Acumulatori inclusi, autonomie 22 min la incarcare 7kW. Card WEB/SNMP inteface IPV4/IPV6 for slot note: specific conditions of aplications on case of NeTYS RT. Manopera modificare circuit de alimentare rack-uri, montare UPS si punere in functiune (PIF). (cabluri, pini reglete, material marunt -- inclus). 2. UPS 10KVA UPS, dubla conversie, 400V. Acumulatori inclusi, autonomie 21 min la incarcare 3,5kW. Card WEB/SNMP inteface IPV4/IPV6 for slot note: specific conditions of aplications on case of NeTYS RT. Manopera modificare circuit de alimentare rack-uri, montare UPS si punere in functiune (PIF). (cabluri, pini reglete, material marunt -- inclus). 3. Priza 3P+N+T, 32A, IP44, montaj inclus. 4. Identificare circuite, masurare, numerotare, etichetare. 5. Automatizare delestare baterii de compensare la schimbare de retea. Manopera programare soft, materiale, executie si montaj inclus. 6. Limitator de maxima si minima tensiune montat in tabloul general pentru circuitul de alimentare cu convertizor de frecventa a motorului trifazat de urcare si coborare scena mobila (montaj si modificare circuit de alimentare inclus). 7. Mentenanta UPS-uri, eliminare praf, verificare acumulatori.
    Achizitii
    87.832,36 RON
    Cantitate: 1
    Unitate masura: bucata
    Reparatii curente necesare retelei electrice
    1. UPS 10KVA UPS, dubla conversie, 400V. Acumulatori inclusi, autonomie 22 min la incarcare 7kW. Card WEB/SNMP inteface IPV4/IPV6 for slot note: specific conditions of aplications on case of NeTYS RT. Manopera modificare circuit de alimentare rack-uri, montare UPS si punere in functiune (PIF). (cabluri, pini reglete, material marunt -- inclus). 2. UPS 10KVA UPS, dubla conversie, 400V. Acumulatori inclusi, autonomie 21 min la incarcare 3,5kW. Card WEB/SNMP inteface IPV4/IPV6 for slot note: specific conditions of aplications on case of NeTYS RT. Manopera modificare circuit de alimentare rack-uri, montare UPS si punere in functiune (PIF). (cabluri, pini reglete, material marunt -- inclus). 3. Priza 3P+N+T, 32A, IP44, montaj inclus. 4. Identificare circuite, masurare, numerotare, etichetare. 5. Automatizare delestare baterii de compensare la schimbare de retea. Manopera programare soft, materiale, executie si montaj inclus. 6. Limitator de maxima si minima tensiune montat in tabloul general pentru circuitul de alimentare cu convertizor de frecventa a motorului trifazat de urcare si coborare scena mobila (montaj si modificare circuit de alimentare inclus). 7. Mentenanta UPS-uri, eliminare praf, verificare acumulatori.