Reparatii curente necesare retelei electrice
SEAPIDStare
DA30000051
Data22 Februarie 2022
Valoare87.832,36 RON
Oferta acceptata
Autoritatea contractantaLocalitateBucuresti, Bucuresti
FurnizorTipul contractuluiServicii
Cod CPV50711000-2 - Servicii de reparare si de intretinere a instalatiilor electrice de constructii (Rev.2)
Descriere:1. UPS 10KVA UPS, dubla conversie, 400V. Acumulatori inclusi, autonomie 22 min la incarcare 7kW.
Card WEB/SNMP inteface IPV4/IPV6 for slot note: specific conditions of aplications on case of NeTYS RT.
Manopera modificare circuit de alimentare rack-uri, montare UPS si punere in functiune (PIF). (cabluri, pini reglete, material marunt -- inclus).
2. UPS 10KVA UPS, dubla conversie, 400V. Acumulatori inclusi, autonomie 21 min la incarcare 3,5kW.
Card WEB/SNMP inteface IPV4/IPV6 for slot note: specific conditions of aplications on case of NeTYS RT.
Manopera modificare circuit de alimentare rack-uri, montare UPS si punere in functiune (PIF). (cabluri, pini reglete, material marunt -- inclus).
3. Priza 3P+N+T, 32A, IP44, montaj inclus.
4. Identificare circuite, masurare, numerotare, etichetare.
5. Automatizare delestare baterii de compensare la schimbare de retea. Manopera programare soft, materiale, executie si montaj inclus.
6. Limitator de maxima si minima tensiune montat in tabloul general pentru circuitul de alimentare cu convertizor de frecventa a motorului trifazat de urcare si coborare scena mobila (montaj si modificare circuit de alimentare inclus).
7. Mentenanta UPS-uri, eliminare praf, verificare acumulatori.
Achizitii87.832,36 RON
Cantitate: 1
Unitate masura: bucata
Reparatii curente necesare retelei electrice
1. UPS 10KVA UPS, dubla conversie, 400V. Acumulatori inclusi, autonomie 22 min la incarcare 7kW.
Card WEB/SNMP inteface IPV4/IPV6 for slot note: specific conditions of aplications on case of NeTYS RT.
Manopera modificare circuit de alimentare rack-uri, montare UPS si punere in functiune (PIF). (cabluri, pini reglete, material marunt -- inclus).
2. UPS 10KVA UPS, dubla conversie, 400V. Acumulatori inclusi, autonomie 21 min la incarcare 3,5kW.
Card WEB/SNMP inteface IPV4/IPV6 for slot note: specific conditions of aplications on case of NeTYS RT.
Manopera modificare circuit de alimentare rack-uri, montare UPS si punere in functiune (PIF). (cabluri, pini reglete, material marunt -- inclus).
3. Priza 3P+N+T, 32A, IP44, montaj inclus.
4. Identificare circuite, masurare, numerotare, etichetare.
5. Automatizare delestare baterii de compensare la schimbare de retea. Manopera programare soft, materiale, executie si montaj inclus.
6. Limitator de maxima si minima tensiune montat in tabloul general pentru circuitul de alimentare cu convertizor de frecventa a motorului trifazat de urcare si coborare scena mobila (montaj si modificare circuit de alimentare inclus).
7. Mentenanta UPS-uri, eliminare praf, verificare acumulatori.