Cuptor L 3/12 cu controller C 450

    SEAP
    ID
    DA26429092
    Data
    24 Septembrie 2020
    Valoare
    24.354,55 RON
    Stare
    Oferta acceptata
    Autoritatea contractantaLocalitate
    Bucuresti, Bucuresti
    FurnizorTipul contractului
    Furnizare
    Cod CPVDescriere:
    Cuptor L 3/12 cu controller C 450 3. Technical specifications Inner dimensions (wxdxh): 160 x 140 x 100 mm Work space1 (bxtxh): 135 x 115 x 75 mm Outer dimensions2 (WxDxH): 385 x 330 x 405 mm Temperature Uniformity: +/- 5 K with closed air inlet in the empty workspace according to DIN 17052-1 at working temperatures > 800°C Volume: 3 liter Weight: 20 kg Power rating: 1,3 kW Supply voltage: 220-240 V, 1/N/PE (2PE) 50/60 Hz Max. operating temperature3: 1200 °C Heat-up time (without load): 60 min. to Tmax (if connected at 230 V, 1/N/PE) 1 Defined space inside furnace where the temperature uniformity is valid. 2 Outer dimensions may vary depending on additional equipment and accessories. Exact dimensions on request. 3 Continuous operation at maximum temperature can lead to increased wear of the heating elements, thermocouples or isolation. We recommend operation at approx. 50 °C below the maximum temperature. 4. Customized furnace design  Housing manufactured from high grade structured stainless steel  Dual shell housing  Exhaust air outlet in the furnace rear wall  Switching of the heating elements by electronic relay  Adjustable air inlet in the door  Door opening supported by springs  Flap door which can be used as work surface while charging  Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2  Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2  Heating fr
    Achizitii
    2.242,35 RON
    Cantitate: 1
    Unitate masura: bucata
    Sistem de ventilatie
    Sistem de ventilatie  Supports the venting of gases and vapours from the furnace chamber  Exhaust air cross section Ø 81,2 mm  Controller B400/B410 and C440/C450 can be used to activate the fan automatically (not possible with L(T) 15)  No combination with protective gas connection and gassing systems  Article number 631000812
    22.112,2 RON
    Cantitate: 1
    Unitate masura: bucata
    Cuptor L 3/12 cu controller C 450
    Cuptor L 3/12 cu controller C 450 3. Technical specifications Inner dimensions (wxdxh): 160 x 140 x 100 mm Work space1 (bxtxh): 135 x 115 x 75 mm Outer dimensions2 (WxDxH): 385 x 330 x 405 mm Temperature Uniformity: +/- 5 K with closed air inlet in the empty workspace according to DIN 17052-1 at working temperatures > 800°C Volume: 3 liter Weight: 20 kg Power rating: 1,3 kW Supply voltage: 220-240 V, 1/N/PE (2PE) 50/60 Hz Max. operating temperature3: 1200 °C Heat-up time (without load): 60 min. to Tmax (if connected at 230 V, 1/N/PE) 1 Defined space inside furnace where the temperature uniformity is valid. 2 Outer dimensions may vary depending on additional equipment and accessories. Exact dimensions on request. 3 Continuous operation at maximum temperature can lead to increased wear of the heating elements, thermocouples or isolation. We recommend operation at approx. 50 °C below the maximum temperature. 4. Customized furnace design  Housing manufactured from high grade structured stainless steel  Dual shell housing  Exhaust air outlet in the furnace rear wall  Switching of the heating elements by electronic relay  Adjustable air inlet in the door  Door opening supported by springs  Flap door which can be used as work surface while charging  Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2  Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2  Heating from two sides by ceramic heating plates with integrated heating wire which is safeguarded against fumes and splashing, and easy to replace  Thermocouple type S 5. Additional equipment in the scope of supply  Over-temperature limiter with manual reset  Adjustable cutout temperature for thermal protection class 2 in accordance with EN60519-2 as temperature limiter to protect the furnace and load 6. Supplied documents  Operating instructions for controller and furnace including:  Installation  First-time operation  Parts list  Operating instructions, maintenance and cleaning description  CE- declaration of conformity according to Low voltage regulation  All documents in English 7. To be provided by customer  Despite good insulation, the furnace radiates heat from its external surfaces. The operator must ensure that this heat is conducted away.  Should gases or vapors escape from the charge, then sufficient air supply and ventilation at the installation location or an appropriate exhaust gas line must be provided.  The size and design of the exhaust air system must be laid out by a ventilation expert. The accident prevention regulations applicable in the country where the furnace is installed must be considered. 8. Non-compliances with customer’s specifications, terms & conditions  No customer’s specifications, terms & conditions considered