SENZOR/TRANSMITTER CO2
SEAPIDStare
DA23145031
Data28 Mai 2019
Valoare2.080 RON
Oferta acceptata
Autoritatea contractantaLocalitateTimisoara, Timis
FurnizorTipul contractuluiFurnizare
Cod CPVDescriere:DeltaOHM HD37 - Transmitter de CO2 in semnal unificat 0…10V - Alimentare la 24 Vdc; cabluri de conectare la PLC si proces - 2 iesiri pe relee pentru semnalizare praguri minimale/maximale CO2 Measurement Principle Double wave length infrared technology (NDIR) CO2 Measurement Range: 0 … 2000ppm;0 … 5000ppm CO2 Accuracy: f.s. 2000ppm •}(50ppm+3% of measurement) at 20°C, 50%RH and 1013hPa; f.s. 5000ppm •}(50ppm+4% of measurement) Temperature Measurement Range: 0 …+50°C Models Temperature Accuracy •}0.3°C Analog Outputs: 0 …10VDC; RL < 500Ω; RL > 10kΩ Digital Output: Type Open-collector (N.O.) Power supply 16…40Vdc or 24Vac •}10%; Absorption <2W Startup Stabilization Time 15 minutes To guarantee the stated; accuracy. Response Time τ63% 120s Wind speed of at least 1m/s. Temperature effect 0.2%/°C CO2 Typical value Atmospheric Pressure effect 1.6%/kPa Deviation compared to the value at 101kPa Long-term Stability 5% of the range / 5 years Typical value Calibration At one point at 0ppm or 400ppm clear air Automatic detection of the applied CO2 level. Working Temperature/Relative Humidity:-5 …+50°C, 0 ... 90%RH without condensation Storage Temperature/Relative Humidity:-10 …+60°C, 0 ... 90%RH without condensation
Achizitii2.080 RON
Cantitate: 1
Unitate masura: bucata
SENZOR/TRANSMITTER CO2
Model: DeltaOHM HD37
- Transmitter de CO2 in semnal unificat 0…10V
- Alimentare la 24 Vdc; cabluri de conectare la PLC si proces
- 2 iesiri pe relee pentru semnalizare praguri minimale/maximale
CO2 Measurement Principle Double wave length infrared technology (NDIR) CO2
Measurement Range: 0 … 2000ppm;0 … 5000ppm CO2
Accuracy: f.s. 2000ppm •}(50ppm+3% of measurement) at 20°C, 50%RH and 1013hPa; f.s. 5000ppm •}(50ppm+4% of measurement)
Temperature Measurement Range: 0 …+50°C Models
Temperature Accuracy •}0.3°C
Analog Outputs: 0 …10VDC; RL < 500Ω; RL > 10kΩ
Digital Output: Type Open-collector (N.O.)
Power supply 16…40Vdc or 24Vac •}10%; Absorption <2W
Startup Stabilization Time 15 minutes
To guarantee the stated; accuracy.
Response Time τ63% 120s Wind speed of at least 1m/s.
Temperature effect 0.2%/°C CO2 Typical value
Atmospheric Pressure effect 1.6%/kPa Deviation compared to the value at 101kPa
Long-term Stability 5% of the range / 5 years Typical value
Calibration At one point at 0ppm or 400ppm clear air
Automatic detection of the applied CO2 level.
Working Temperature/Relative Humidity:-5 …+50°C, 0 ... 90%RH without condensation
Storage Temperature/Relative Humidity:-10 …+60°C, 0 ... 90%RH without condensation